Nordhall Office Systems

Network Setup

Configuring Nordhall devices on managed office networks: addressing, print queues, scan destinations and certificates.

Static addressing

From the panel: Settings → Network → IPv4 → Manual. A reservation on the DHCP server is preferable to a static entry on the device, because it survives a factory reset.

Address   10.20.4.17
Mask      255.255.255.0
Gateway   10.20.4.1
DNS       10.20.1.10, 10.20.1.11

Print queue on a server

Use the Nordhall Universal Driver 7.4 or later. Raw TCP port 9100 is the default; LPR is supported for legacy spoolers.

ProtocolPortNotes
Raw / JetDirect9100Recommended
LPR515Queue name lp
IPP631Required for driverless printing
Device web panel443HTTP on 80 redirects

Scan to SMB

Create a dedicated service account with write-only access to the target share. The device stores the password in its protected area; it cannot be read back from the panel.

SMB1 is disabled in firmware 3.x and later. Shares that still require it will fail with error E-412.

802.1X and certificates

The device holds up to 16 certificates. Renewal is manual: upload the new chain, then switch the active profile. Removing the old certificate before switching will drop the device off the network.

Renewal order